Inert Gas Fire Suppression System
INERT GAS
Fire Suppression System
- Conventional
- Addressable
The Rotarex Firetec INEREX® Inert Gas Fire Suppression System uses nitrogen, argon, or inert gas mixtures to suppress fire by reducing oxygen levels within a protected enclosure. It provides clean, residue-free fire protection for critical facilities such as data centers, server rooms, and control rooms. Available configurations may support 200-bar or 300-bar cylinders, depending on the system design
Inert Gas Fire Suppression System

The evacuation-area signage is a visual warning used with fire suppression systems to direct occupants to leave the protected area promptly during an alarm or agent-discharge event.
BRAND:KIDDEFIRE SYSTEM
The Kidde DC-9103E-KID Heat Detector is a conventional fire detection device that detects abnormal increases in temperature. It can operate using rate-of-rise and fixed-temperature detection and is programmable for A1R, A2S, or BS heat-detector classes.
BRAND:KIDDEFIRE SYSTEM
The Kidde Alarm Bell is an audible notification device used in fire alarm and fire suppression systems to provide a loud warning when an alarm condition occurs, alerting occupants to take appropriate emergency action.
BRAND:KIDDEFIRE SYSTEM
The Kidde Abort Station is a manual control device used in fire suppression systems to temporarily interrupt or delay automatic agent discharge while the abort button is held, depending on the system configuration. The Kidde Model 878752 features a highly visible yellow, momentary push button.
BRAND:KIDDEFIRE SYSTEM
A Kidde Manual Pull Station is a manual initiating device used to allow personnel to manually activate a fire alarm or fire suppression system during an emergency. Kidde Series 3300 stations use dual-action operation to help reduce accidental activation.
BRAND:KIDDEFIRE SYSTEM
The AEGIS™-PHX control panel is a conventional fire alarm and suppression control unit designed to monitor, control, and manage fire suppression systems, including clean-agent, CO₂, and other special-hazard applications. It provides programmable inputs and outputs, event logging, and a 4-line × 40-character LCD interface for system status, configuration, diagnostics, and testing.
BRAND:KIDDEFIRE SYSTEM
The gas discharge signage is a visual warning device used with clean-agent fire suppression systems to indicate that the extinguishing agent has been discharged into the protected area, warning personnel not to enter.
BRAND:KIDDEFIRE SYSTEM
The Kidde Horn Strobe is a fire alarm notification device that combines an audible horn and visual strobe light to alert occupants when a fire alarm condition occurs. It is part of Kidde’s fire alarm notification device portfolio.
BRAND:KIDDE FIRE SYSTEM
A Kidde Zone 2 smoke detector is a fire detection device designed to detect smoke and initiate an alarm signal when smoke is present within a protected area. It is used as part of a fire detection and alarm system.
BRAND: KIDDE FIRE SYSTEM
A Kidde discharge nozzle is a specially designed component of a clean-agent fire suppression system that distributes the extinguishing agent throughout the protected area in a calculated discharge pattern. Kidde offers nozzle configurations such as 180° and 360°, selected according to system design requirements.
BRAND:KIDDEFIRE SYSTEM
The Manifold will collect and combine the discharge flow from multiple connected cylinders and directs the inert gas into the system's distribution piping. Its design must be compatible with the system's specified operating pressure and configuration. BRAND:ROTAREX FIRETEC
The Clamp for Manifold will secures the manifold to its mounting support, helping keep the pipe assembly stable and properly positioned during installation and operation
BRAND:ROTAREX FIRETEC
The Manual Release Device will provide a manual method of actuating the cylinder valve to release the inert gas when required, following the system's approved emergency operating procedure.
BRAND:ROTAREX FIRETEC
The Electromagnetic Release Device will electrically actuates the compatible cylinder valve when an authorized release signal is received from the suppression control system, enabling automatic system discharge when configured accordingly.
BRAND:ROTAREX FIRETEC
The pressure gauge displays cylinder pressure for visual monitoring, while the pressure switch provides an electrical signal for pressure monitoring or alarm functions, depending on the model and system configuration.
BRAND:ROTAREX FIRETEC
The Discharge Hose will connect the cylinder valve or regulator assembly to the manifold, providing a flexible, pressure-rated path for inert gas discharge.
BRAND:ROTAREX FIRETEC
The Pilot Hose will carry pressurized actuating gas between compatible release devices and cylinder valve actuators to initiate or transmit the release sequence. BRAND:ROTAREX FIRETEC
The Bracket for Manifold will support and position the manifold securely on its mounting structure, helping maintain proper alignment and stability.
BRAND:ROTAREX FIRETEC
The Discharge Pressure Regulator will reduce and regulates the high-pressure inert gas released from the cylinders to a controlled discharge pressure. Rotarex's INEREX® regulator technology is designed to maintain a discharge pressure of approximately 40–60 bar, depending on the specified model and Configuration.
BRAND:ROTAREX FIRETEC
The Bleed Valve will allow to trapped pressure in the compatible pneumatic release circuit to be vented in accordance with the manufacturer's procedure, supporting safe servicing and resetting.
BRAND:ROTAREX FIRETEC
The Inert Gas Cylinder Tank will stores the inert extinguishing gas under high pressure until system activation. Depending on the approved system design, the agent may be IG-01, IG-100, IG-55, or IG-541. Rotarex INEREX® systems include configurations designed for 200-bar or 300-bar storage.
BRAND:ROTAREX FIRETEC
The Wall Mounting Rail will holds the cylinder securely in its designated installation position, helping prevent movement and maintaining the required mounting arrangement.
BRAND:ROTAREX FIRETEC
The Pneumatic Release Device uses a pneumatic pressure to actuate a compatible cylinder valve. It can be used in a pneumatic release arrangement or as part of a coordinated multi-cylinder release sequence, according to the approved system design.
BRAND:ROTAREX FIRETEC
The Support for Cylinder is designed to provide stable support and positioning for the inert gas cylinder within the Rotarex Firetec INEREX® fire suppression system. It helps maintain the cylinder's designated installation position and supports secure mounting as part of the complete system assembly.
Brand: ROTAREX FIRETEC
Fire Detection & Alarm System
(Conventional)

The evacuation-area signage is a visual warning used with fire suppression systems to direct occupants to leave the protected area promptly during an alarm or agent-discharge event.
BRAND:KIDDE FIRE SYSTEM
The Kidde DC-9103E-KID Heat Detector is a conventional fire detection device that detects abnormal increases in temperature. It can operate using rate-of-rise and fixed temperature detection and is programmable for A1R, A2S, or BS heat-detector classes.
BRAND:KIDDE FIRE SYSTEM
The Kidde Alarm Bell is an audible notification device used in fire alarm and fire suppression systems to provide a loud warning when an alarm condition occurs, alerting occupants to take appropriate emergency action.
BRAND:KIDDE FIRE SYSTEM

The Kidde Control Head is an actuator mounted on the suppression cylinder valve that initiates agent release when the fire suppression system is activated. Depending on the system, it may be electrically, pneumatically, or manually operated.
BRAND:KIDDE FIRE SYSTEM

The Kidde Fire Systems suppression cylinder is a pressurized steel container designed to store and discharge HFC 227ea (FM-200™) clean agent for fire suppression systems. The agent is stored under pressure and released through the system piping and nozzles when activated.
BRAND:KIDDE FIRE SYSTEM

The Kidde Abort Station is a manual control device used in fire suppression systems to temporarily interrupt or delay automatic agent discharge while the abort button is held, depending on the system configuration. The Kidde Model 878752 features a highly visible yellow, momentary push button.
BRAND:KIDDE FIRE SYSTEM

A Kidde Manual Pull Station is a manual initiating device used to allow personnel to manually activate a fire alarm or fire suppression system during an emergency. Kidde Series 3300 stations use dual-action operation to help reduce accidental activation.
BRAND:KIDDE FIRE SYSTEM

The AEGIS™-PHX control panel is a conventional fire alarm and suppression control unit designed to monitor, control, and manage fire suppression systems, including clean-agent, CO₂, and other special-hazard applications. It provides programmable inputs and outputs, event logging, and a 4-line × 40-character LCD interface for system status, configuration, diagnostics, and testing.
BRAND:KIDDE FIRE SYSTEM

The Gas Discharge signage is a visual warning device used with clean-agent fire suppression systems to indicate that the extinguishing agent has been discharged into the protected area, warning personnel not to enter.
BRAND:KIDDE FIRE SYSTEM

The Kidde Horn Strobe is a fire alarm notification device that combines an audible horn and visual strobe light to alert occupants when a fire alarm condition occurs. It is part of Kidde’s fire alarm notification device portfolio. BRAND:KIDDE FIRE SYSTEM

A Kidde Zone 2 SmokeDetector is a fire detection device designed to detect smoke and initiate an alarm signal when smoke is present within a protected area. It is used as part of a fire detection and alarm system.
BRAND: KIDDE FIRE SYSTEM

A Kidde discharge nozzle is a specially designed component of a clean-agent fire suppression system that distributes the extinguishing agent throughout the protected area in a calculated discharge pattern. Kidde offers nozzle configurations such as 180° and 360°, selected according to system design requirements.
BRAND: KIDDE FIRE SYSTEM
Fire Detection & Alarm System
(Addressable)
The Kidde SmartOne® Addressable Heat Detector is an intelligent, individually addressable detector designed to
sense abnormal heat conditions and communicate its status to a compatible Kidde fire alarm control unit through the
Signaling Line Circuit (SLC). It is particularly useful in areas where smoke detection may be affected by dust, steam, or other airborne contaminants, providing reliable heat-based detection, precise device identification, and improved system monitoring.
BRAND: KIDDE FIRE SYSTEM
The Kidde Alarm Bell is an audible notification device used in fire alarm and fire suppression systems to provide a loud warning when an alarm condition occurs, alerting occupants to take appropriate emergency action.
BRAND: KIDDE FIRE SYSTEM

The Kidde SmartOne® Alarm Signal Module (ASM) used to provide a supervised notification circuit for compatible audible and visual alarm appliances, such as horns and strobes. It enables the fire alarm control system to activate and monitor connected notification devices, helping provide reliable alarm signaling and improved system monitoring throughout the protected area.
BRAND: KIDDE FIRE SYSTEM

A Kidde Manual Pull Station is a manual initiating device used to allow personnel to manually activate a fire alarm or
fire suppression system during an emergency. Kidde Series 3300 stations use dual-action operation to help reduce
accidental activation.
BRAND: KIDDE FIRE SYSTEM

The Kidde Addressable Fire Detection and Alarm System (FDAS) Panel serves as the central control unit that receives, processes, and monitors signals from individually addressable detectors and modules connected through the system’s signaling line circuit (SLC). It identifies the specific device reporting an alarm, trouble, or supervisory condition, providing accurate event identification, centralized monitoring, and faster system diagnostics.
BRAND: KIDDE FIRE SYSTEM
The Kidde Horn Strobe is a fire alarm notification device that combines an audible horn and visual strobe light to alert occupants when a fire alarm condition occurs. It is part of Kidde’s fire alarm notification device portfolio.
BRAND: KIDDE FIRE SYSTEM
The Kidde Addressable Loop 1 Smoke Detector is an addressable smoke detection device designed to detect smoke at an early stage and transmit its individual device status to a compatible Kidde fire alarm control panel through the addressable loop. Its individual addressing allows the system to identify the specific detector in alarm or trouble, providing faster event identification, centralized monitoring, and improved fire detection response.
BRAND: KIDDE FIRE SYSTEM